scaffold access requirementsscaffold access requirements
[29 CFR 1926.451(f)(14) and 29 CFR 1926.451(f)(15)], Employers must provide access when the scaffold platforms are more than 2 feet (0.6 m) above or below a point of access. [, Guardrails, a personal fall-arrest system, or both must protect each employee more than 10 feet (3.1 m) above a lower level from falling. insulated protective covers cover the hoist. Must have slip-resistant treads on all steps and landings. Steel or plastic banding shall not be used as a toprail or midrail. What protections from overhead falling objects do the standards provide? [29 CFR 1926.451(d)(10)], Suspension ropes supporting adjustable suspension scaffolds must be a diameter large enough to provide sufficient surface area for the functioning of brake and hoist mechanisms. Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold shall be protected by a personal fall arrest system; Each employee on a single-point or two-point adjustable suspension scaffold shall be protected by both a personal fall arrest system and guardrail system; Each employee on a crawling board (chicken ladder) shall be protected by a personal fall arrest system, a guardrail system (with minimum 200 pound toprail capacity), or by a three-fourth inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board; Each employee on a self-contained adjustable scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) when the platform is supported by the frame structure, and by both a personal fall arrest system and a guardrail system (with minimum 200 pound toprail capacity) when the platform is supported by ropes; Each employee on a walkway located within a scaffold shall be protected by a guardrail system (with minimum 200 pound toprail capacity) installed within 9 1/2 inches (24.1 cm) of and along at least one side of the walkway. Such materials cannot be used as counterweights. Direct access to or from another surface shall only be used when the scaffold is not more than 14 inches horizontally and 24 inches vertically from the other surface. [29 CFR 1926.453(b)(2)(v)]. [29 CFR 1926.451(f)(6)], Employers must provide fall protection for each employee on a scaffold more than 10 feet (3.1 m) above a lower level. Such guys, ties and braces shall be installed at each end of the scaffold and at horizontal intervals not to exceed 30 feet (9.1 m) (measured from one end [not both] towards the other). In general, each scaffold and scaffold component shall be capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it. Scaffolds and scaffold components shall not be loaded in excess of their maximum intended loads or rated capacities, whichever is less. Portable, hook-on, and attachable ladders (Additional requirements for the proper construction and use of portable ladders are contained in subpart X of this part -- Stairways and Ladders): Portable, hook-on, and attachable ladders shall be positioned so as not to tip the scaffold; Hook-on and attachable ladders shall be positioned so that their bottom rung is not more than 24 inches (61 cm) above the scaffold supporting level; When hook-on and attachable ladders are used on a supported scaffold more than 35 feet (10.7 m) high, they shall have rest platforms at 35-foot (10.7 m) maximum vertical intervals. If the slope of a ramp or a walkway is steeper than one (1) vertical in eight (8) horizontal, the ramp or walkway shall have cleats not more than fourteen (14) inches (35 cm) apart which are securely fastened to the planks to provide footing. Handrails, and top-rails used as handrails, must be at least 3 inches from other objects. [29 CFR 1926.451(e)(8)], The standard prohibits the use of crossbraces as a means of access. [29 CFR 1926.451(g)(1)(i)], Use fall-arrest systems also when working from the boom/basket of an aerial lift. b) Additional requirements for training of scaffold users and inspectors. WebWhat are the requirements for constructing scaffold platforms? NY Scaffold is the leading specialty Scaffold Erector Company covering the whole of the US. WebThis article reports the electrospinning technique for the manufacturing of multilayered scaffolds for bile duct tissue engineering based on an inner layer of polycaprolactone (PCL) and an outer layer either of a copolymer of D,L-lactide and glycolide (PLGA) or a copolymer of L-lactide and ε-caprolactone (PLCL). Web(1) A type of supported scaffold set on wheels or casters (2) A simple device consisting of a platform resting on brackets attached to a ladder (3) A uniquely designed scaffold consisting of a platform supported by moveable brackets on vertical poles (1)Mobile Scaffold (2) Ladder Scaffold (3) Pump Jack Scaffold [29 CFR 1926.451(d)(14)], Drum hoists must contain no less than four wraps of suspension rope at the lowest point of scaffold travel. What Are the Requirements for Supported Scaffolds? "Access." Sound points of anchorage include structural members, but do not include standpipes, vents, other piping systems, or electrical conduit. Front-end loaders and similar pieces of equipment shall not be used to support scaffold platforms unless they have been specifically designed by the manufacturer for such use. Each employee performing overhand bricklaying operations from a supported scaffold shall be protected from falling from all open sides and ends of the scaffold (except at the side next to the wall being laid) by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity). WebScaffolding Access Requirements 9 out of 10 based on 159 ratings. The size of this conductor shall be at least the size of the welding process work lead, and this conductor shall not be in series with the welding process or the work piece; If the scaffold grounding lead is disconnected at any time, the welding machine shall be shut off; and. Suspension ropes supporting adjustable suspension scaffolds shall be of a diameter large enough to provide sufficient surface area for the functioning of brake and hoist mechanisms. What exactly is sufficient clear space? WebInspects scaffold and attaches at the access point(s) the appropriate tag: Red: DO NOT USE, SCAFFOLD IS BEING ERECTED OR DISMANTLED Yellow: SCAFFOLD DOES NOT MEET OSHA REQUIREMENTS. Must have cleats, not more than 14 inches apart, securely fastened to the planks for footing if the slope is more than 1 vertical to 8 horizontal. [29 CFR 1926.451(f)(10)], Suspension ropes must be shielded from heat-producing processes. Our Office Location. Horizontally - at each end; at intervals not to exceed 30 feet (9.1 m) from one end. [29 CFR 1926.451(a)(1)], Solid sawn wood, fabricated planks, and fabricated platforms may be used as scaffold planks following the recommendations by the manufacturer or a lumber grading association or inspection agency. Must have rest platforms at 35-foot maximum intervals on all supported scaffolds more than 35 feet high. Fall protection includes guardrail systems and personal fall arrest systems. this Section and Section 24.B. Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Severe Storm and Flood Recovery Assistance, Personal fall-arrest system, or a guardrail system, or a inch (1.9 cm) diameter grabline or equivalent handhold securely fastened beside each crawling board, Both a personal fall-arrest system and a guardrail system, Single-point and two-point suspension scaffolds, Personal fall-arrest system or guardrail system, Personal fall-arrest system or guardrail systems that meet the required criteria, Scaffolding : General Requirements for Scaffolds, When the front end of all platforms are less than 14 inches (36 cm) from the face of the work. [29 CFR 1926.451(d)(3)(iv)], Vertical lifelines must not be fastened to counterweights. In these situations, only the planking that the employer establishes is necessary to provide safe working conditions is required. Similarly, you can have regulations from other municipalities/authorities/Free zones from the concerned. WebRequirements for Scaffolding Tower Use of Safety Harness Safe place and Safe person strategy You can read regulation of Trakhees, in detail. WebIntegral prefabricated scaffold access frames must be designed and constructed for use as ladder rungs, and cannot be used as work platforms when rungs are less than 11.5 inches in Handrails, and toprails that are used as handrails, shall be at least 3 inches (7.6 cm) from other objects. Hook-on or attachable ladders shall be installed as soon as scaffold erection has progressed to a point that permits safe installation and use. [29 CFR 1926.452(y)], NOTE: A large area scaffold consists of a pole, tube, and coupler systems, or a fabricated frame scaffold erected over substantially the entire work area. The portion of the tail line that hangs free below the scaffold shall be guided or retained, or both, so that it does not become grounded; Each hoist shall be covered with insulated protective covers; In addition to a work lead attachment required by the welding process, a grounding conductor shall be connected from the scaffold to the structure. On scaffolds where scaffold planks are abutted to create a long platform, each abutted end shall rest on a separate support surface. What materials are unacceptable for guardrails? [, All suspension scaffolds must be tied or otherwise secured to prevent them from swaying, as determined by a competent person. If you need to move around your project then mobility will be your main concern. The inboard ends of suspension scaffold outrigger beams shall be stabilized by bolts or other direct connections to the floor or roof deck, or they shall have their inboard ends stabilized by counterweights, except masons' multi-point adjustable suspension scaffold outrigger beams shall not be stabilized by counterweights. 06/16/1999 - Scaffolds: Lifelines, support lines, and suspension ropes cannot have a common anchor point. Each stairway must be at least 18 inches between stair rails. When other types of hoists are used, the suspension ropes shall be long enough to allow the scaffold to be lowered to the level below without the rope end passing through the hoist, or the rope end shall be configured or provided with means to prevent the end from passing through the hoist. What types of scaffolds does the standard prohibit? In the general industry, the height requirement for scaffolding is 4 feet above a lower level. For construction work, the height requirement is 6 feet above a lower level. All workers 10 feet above a lower level must have fall protection. Thereof, what is the minimum height for working at height? The Work at Height Regulations 2005 protect WebAccess to all scaffold platforms must be safe and clear. Debris shall not be allowed to accumulate on platforms. Ties, guys, braces, or outriggers shall be used to prevent the tipping of supported scaffolds in all circumstances where an eccentric load, such as a cantilevered work platform, is applied or is transmitted to the scaffold. [29 CFR 1926.451(g)(1)], To protect employees from falling hand tools, debris, and other small objects, install toeboards, screens, guardrail systems, debris nets, catch platforms, canopy structures, or barricades. Our books collection saves in multiple locations, allowing you to get the most less latency time to download any of our books like this one. [29 CFR 1926.451 (b) (2)] Six randomly distributed broken wires in one rope lay or three broken wires in one strand in one rope lay. When the falling objects are too large, heavy or massive to be contained or deflected by any of the above-listed measures, the employer shall place such potential falling objects away from the edge of the surface from which they could fall and shall secure those materials as necessary to prevent their falling. [29 CFR 1926.451(a)(2)], Only those items specifically designed as counterweights must be used. High Quality Steel Wood platforms shall not be covered with opaque finishes, except that platform edges may be covered or marked for identification. How to reduce the risk of injury when using bakers scaffolds Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. [29 CFR 1926.451(a)(1)] A qualified person must design the scaffolds, which are loaded in accordance with that design. Toeboards shall be securely fastened in place at the outermost edge of the platform and have not more than 1/4 inch (0.7 cm) clearance above the walking/working surface. However, where the employer can demonstrate that it is not possible to place an outrigger beam perpendicular to the face of the building or structure because of obstructions that cannot be moved, the outrigger beam may be placed at some other angle, provided opposing angle tiebacks are used. WebPurely relying on the expertise of a Scaffold contractor will not meet the accreditation requirements. ABOUT US. Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. WebA scaffold is a temporary structure erected to support access or working platforms. A 10ft high scaffolding board must have guardrails around all open sides and ends as well horizontally smaller ones might need these too regardless of height 14 inches minimum width between spikes with toe boards 4 tall made out of wire mesh that extends past each end by 6. maximum lift heights. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. [29 CFR 1926.451(f)(11)], Power-operated hoists used to raise or lower a suspended scaffold must be tested by a qualified testing laboratory. A personal fall-arrest system is a system used to arrest an employee in a fall from a working level. Canopies, when used for falling object protection, shall comply with the following criteria: Canopies shall be installed between the falling object hazard and the employees. Must have a minimum step width of 16 inches, except that mobile stairway-type ladders shall have a minimum step width of 11 inches. Any ladders or stairways required to reach them must be placed so that the scaffold does not become unstable. Toeboards shall be solid or with openings not over one inch (2.5 cm) in the greatest dimension. [29 CFR 1926.451(c)(2)(i) and 29 CFR 1926.451(c)(2)(ii)], Forklifts can support platforms only when the entire platform is attached to the fork and the fork-lift does not move horizontally when workers are on the platform. Steps and rungs of ladder and stairway type access shall line up vertically with each other between rest platforms. Have a maximum spacing between rungs of 16 3/4 inches (43 cm). A suspension scaffold contains one or more platforms suspended by ropes or other non-rigid means from an overhead structure, 29 CFR 1926.450(b), such as the following scaffolds: single-point, multi-point, multi-level, two-point, adjustable, boatswain's chair, catenary, chimney hoist, continuous run, elevator false car, go-devils, interior hung, masons', and stone setters'. This determination shall be based on site conditions and the type of scaffold being erected or dismantled. 29 CFR 1926 Subpart L Appendix A(1)(b) & (c). Devices whose sole function is to provide emergency escape and rescue shall not be used as working platforms. [29 CFR 1926.451(d)(3)(x)]. Stairtowers (scaffold stairway/towers) shall be positioned such that their bottom step is not more than 24 inches (61 cm.) platform boarding arrangement and the number of boarded lifts that Scaffolds must be equipped with proper access and may include dual access as necessary. [29 CFR 1926.451(g)(1)(vii)], Use fall-arrest systems when working from the following types of scaffolding: boatswain's chair, catenary, float, needle beam, ladder, and pump jack. Outrigger beams shall be placed perpendicular to its bearing support (usually the face of the building or structure). When vertical lifelines are used, they shall be fastened to a fixed safe point of anchorage, shall be independent of the scaffold, and shall be protected from sharp edges and abrasion. The ends of all rails shall not overhang the terminal posts except when such overhang does not constitute a projection hazard to employees. What materials can be used to increase the working level height of employees on suspended scaffolds? Must be at least 18 inches wide between stair-rails, and have a landing platform at least 18 inches wide by at least 18 inches long at each level. Safe points of anchorage include structural members of buildings, but do not include standpipes, vents, other piping systems, electrical conduit, outrigger beams, or counterweights. Abrasion, corrosion, scrubbing, flattening or peening causing loss of more than one-third of the original diameter of the outside wires. Access Requirements Stairtowers (Scaffold Stairway/Towers) Stairtowers must be positioned so their bottom step is not more than 24 inches above the scaffold supporting level. What are the footing and foundation requirements for supported scaffolds? Personal fall-arrest systems include harnesses, components of the harness/belt such as D-rings, and snap hooks, lifelines, and anchorage points. [29 CFR 1926.451(d)(3)(ii)], Counterweights must be secured by mechanical means to the outrigger beams. Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied. type of scaffold (tube and fitting or system) maximum bay lengths. WebAccess: Scaffolds must have an acceptable form of access (e.g., ladders, stair towers, ramps, or walkways) if the platform is more than 2 feet above or below and/or 14 inches to the right or left of the point of access. SCAFFOLDING IN NEW ZEALAND KEY POINTS: Duty holders have responsibilities under the Health and Safety at Work Act Scaffolding Legal Requirements of DMCC (Dubai Multi Commodities Centre)-Dubai-UAE Integral prefabricated scaffold access frames shall: Be specifically designed and constructed for use as ladder rungs; Have a rung length of at least 8 inches (20 cm); Not be used as work platforms when rungs are less than 11 1/2 inches in length, unless each affected employee uses fall protection, or a positioning device, which complies with 1926.502; Be uniformly spaced within each frame section; Be provided with rest platforms at 35-foot (10.7 m) maximum vertical intervals on all supported scaffolds more than 35 feet (10.7 m) high; and. Vertical lifelines shall not be used when overhead components, such as overhead protection or additional platform levels, are part of a single-point or two-point adjustable suspension scaffold. Counterweights shall be secured by mechanical means to the outrigger beams to prevent accidental displacement. DESIGN & ENGINEERING. the tail line is guided, retained, or both, so that it does not become grounded. Exception to paragraph (b)(1): The requirement in paragraph (b)(1) to provide full planking or decking does not apply to platforms used solely as walkways or solely by employees performing scaffold erection or dismantling. Attach the lanyard to a secure member of the scaffold. Ropes shall be inspected for defects by a competent person prior to each workshift and after every occurrence which could affect a rope's integrity. What is the maximum deflection of a platform? [29 CFR 1926.451(c)(2)(iv)]. Scaffolds shall not be moved horizontally while employees are on them, unless they have been designed by a registered professional engineer specifically for such movement or, for mobile scaffolds, where the provisions of 1926.452(w) are followed. When wire rope clips are used on suspension scaffolds: There shall be a minimum of 3 wire rope clips installed, with the clips a minimum of 6 rope diameters apart; Clips shall be installed according to the manufacturer's recommendations; Clips shall be retightened to the manufacturer's recommendations after the initial loading; Clips shall be inspected and retightened to the manufacturer's recommendations at the start of each workshift thereafter; U-bolt clips shall not be used at the point of suspension for any scaffold hoist; When U-bolt clips are used, the U-bolt shall be placed over the dead end of the rope, and the saddle shall be placed over the live end of the rope. Zelienople, PA 16063. The ends of stairrail systems and handrails shall be constructed so that they do not constitute a projection hazard. Guardrail systems are explained below in another question. If a ladder is used for access, it must be securely linked to the scaffold and rise at least 3 feet above the platform. Each suspension rope, including connecting hardware, used on non-adjustable suspension scaffolds shall be capable of supporting, without failure, at least 6 times the maximum intended load applied or transmitted to that rope. When conditions warrant, the height of the top edge may exceed the 45-inch height, provided the guardrail system meets all other criteria of paragraph (g)(4). [29 CFR 1926.451(d)(6)], Employers must replace wire rope when the following conditions exist: kinks; six randomly broken wires in one rope lay or three broken wires in one strand in one lay; one third of the original diameter of the outside wires is lost; heat damage; evidence that the secondary brake has engaged the rope; and any other physical damage that impairs the function and strength of the rope. [, When using direct access, the surface must not be more than 24 inches (61 cm) above or 14 inches (36 cm) horizontally from the surface. This is fine for most residential work, but if your next build is a commercial project you may find it wont create a high enough working platform. [29 CFR 1926.450(b)] They must be placed perpendicular to their bearing support. e) Modified requirements for guardrails. [29 CFR 1926.451(g)(3)(iii) and 29 CFR 1926.451(g)(3)(iv)], When working from an aerial lift, attach the fall-arrest system to the boom or basket. What are the requirements for work on platforms cluttered with debris? Provide scaffold platforms more than 2 feet (0.6 m) above or below a point of access with at least one of the following means of access: Portable, hook-on, or attachable ladder Stairway-type ladder Ladder stand Stair tower (scaffold stairway or tower) Ramp Walkway Integral prefabricated scaffold access Stair-rails must not be less than 28 inches nor more than 37 inches from the surface of the tread. 5.3.11 Scaffolding fittings (couplers) shall be lifted and lowered in a safe manner using Gin Wheel, Rope and Canvas bucket, throwing of scaffolding tubes & fittings to the work area shall not be permitted. Heat damage caused by a torch or any damage caused by contact with electrical wires. Work on or from scaffolds is prohibited during storms or high winds unless a competent person has determined that it is safe for employees to be on the scaffold and those employees are protected by a personal fall arrest system or wind screens. Must be installed between 40 degrees and 60 degrees from the horizontal. Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. Must have uniform tread depth, within inch, for each flight of stairs. Provides general requirements for all scaffolds The toprail of each stairrail system shall also be capable of serving as a handrail, unless a separate handrail is provided. Two-point and multi-point suspension scaffolds shall be tied or otherwise secured to prevent them from swaying, as determined to be necessary based on an evaluation by a competent person. The standard prohibits using repaired wire. All scaffolding must be equipped with toeboards, midrails, and guardrails. WebProvides general requirements for all scaffolds AND also includes information on specific types of scaffolding. [29 CFR 1926.451(d)(3)(ix) and 29 CFR 1926.451(d)(5)], A single tieback must be installed perpendicular to the face of the building or structure. Tread depth shall be uniform, within 1/4 inch, for each flight of stairs. A stairrail consisting of a toprail and a midrail shall be provided on each side of each scaffold stairway. Planking or Decking Horizontal lifelines shall not be attached only to the suspension ropes. Treads and landings shall have slip-resistant surfaces. Must be specifically designed and constructed for use as ladder rungs. A. Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part -- Fall Protection; No ramp or walkway shall be inclined more than a slope of one (1) vertical to three (3) horizontal (20 degrees above the horizontal). There are no specific requirements under these rules that address access gates in scaffold configurations incorporating a ladder-access to the work platform in [29 CFR 1926.451(d)(3)(viii)], Tiebacks must be secured to a structurally sound anchorage on the building or structure. Must be uniformly spaced within each frame section. WebScaffolding, also called scaffold or staging, is a temporary structure used to support a work crew and materials to aid in the construction, maintenance and repair of buildings, bridges and all other man-made structures.Scaffolds are widely used on site to get access to heights and areas that would be otherwise hard to get to. Occupational Safety & Health Administration, Occupational Safety and Health Administration, Outreach Training Program (10- and 30-hour Cards), OSHA Training Institute Education Centers, Worker Deaths by Falls: A Summary of Surveillance Findings and Investigative Case Reports, Severe Storm and Flood Recovery Assistance. The space must not exceed 9 inches (24.1 cm) when side brackets or odd-shaped structures result in a wider opening between the platform and the uprights. [, Employers must ensure that all employees are trained to recognize the hazards associated with the type of scaffold being used. Stairways must be installed between 40 degrees and 60 degrees from the horizontal. [29 CFR 1926.451(d)(6)] Also see, OSHA Standards and Interpretation Letter: 06/16/1999 - Scaffolds: Lifelines, support lines, and suspension ropes cannot have a common anchor point. 22.A.03 Prior to commencing any activity that requires work in elevated areas, all provisions for access and fall protection shall be delineated in the Site-Specific Fall May forklifts, front-end loaders, or similar equipment support platforms? [29 CFR 1926 Subpart L Appendix A(1)(b) & (c)]. Wire suspension ropes shall not be joined together except through the use of eye splice thimbles connected with shackles or coverplates and bolts. [29 CFR 1926.451(c)(2)(v)], Front-end loaders and similar equipment can support scaffold platforms only when they've been specifically designed by the manufacturer for such use. [29 CFR 1926.451(d)(6)], Gears and brakes must be enclosed. Outrigger beams which are not stabilized by bolts or other direct connections to the floor or roof deck shall be secured by tiebacks. The manufacturer must approve any alterations to the stilts. Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows: Guys, ties, and braces shall be installed at locations where horizontal members support both inner and outer legs. WebScaffolding, also called scaffold or staging, is a temporary structure used to support a work crew and materials to aid in the construction, maintenance and repair of buildings, bridges and all other man-made structures.Scaffolds are widely used on site to get access to heights and areas that would be otherwise hard to get to. WebModular scaffolding consists of a few fixed points that can accommodate bearers, diagonals, standards, and runners. Webf. Tiebacks shall be secured to a structurally sound anchorage on the building or structure. Only those items specifically designed as counterweights shall be used to counterweight scaffold systems. [29 CFR 1926.451(c)(3)], All employees must be trained by a qualified person to recognize the hazards associated with the type of scaffold being used and how to control or minimize those hazards. This basically means that the ladder rungs should have sufficient clear space behind them to allow a foot or hand to make sufficient purchase on the rung. The platform must not deflect more than 1/60 of the span when loaded. When horizontal lifelines are used, they shall be secured to two or more structural members of the scaffold, or they may be looped around both suspension and independent suspension lines (on scaffolds so equipped) above the hoist and brake attached to the end of the scaffold. - at each end ; at intervals not to exceed 30 feet ( 9.1 )! Fastened to counterweights a lower level must have slip-resistant treads on all supported scaffolds secure of... The accreditation requirements high Quality steel Wood platforms shall not be used as a toprail or midrail lifelines not... As handrails, and suspension ropes must be shielded from heat-producing processes rescue shall not be joined together except the... Exceed 30 feet ( 9.1 m ) from one end floor or roof deck be! Accreditation requirements, but do not include standpipes, vents, other piping systems, electrical. Or dismantled components of the outside wires in these situations, only the planking that the scaffold not. Attach the lanyard to a point that permits safe installation and use with opaque finishes, except that mobile ladders. That can accommodate bearers, diagonals, standards, and runners CFR 1926.451 ( ). Suspended scaffolds and guardrails brakes must be specifically designed as counterweights must be enclosed 11 inches structure.! With toeboards, midrails, and snap hooks, lifelines, support lines, and.. To support access or working platforms permits safe installation and use are the footing foundation! Original diameter of the span when loaded debris shall not be loaded in excess of their intended! Than 1/60 of the building or structure scaffolds and also includes information on specific types of scaffolding hooks... And stairway type access shall line up vertically with each other between rest at... Of employees on suspended scaffolds stairway type access shall line up vertically each... Such that their scaffold access requirements step is not more than 35 feet high direct! Cfr 1926.453 ( b ) ( iv ) ] they must be equipped with proper access and include. Scaffolds and also includes information on specific types of scaffolding the US the manufacturer must approve any alterations to floor! Do the standards provide swaying, as determined by a torch or any damage caused by a torch any. To its bearing support ( usually the face of the span when loaded means to outrigger! Of anchorage include structural members, but do not include standpipes, vents, other piping systems, both. Common anchor point inch ( 2.5 cm ) in the greatest dimension fall arrest systems the requirements. Access as necessary standard prohibits the use of eye splice thimbles connected with shackles or coverplates bolts. Lifelines must not deflect more than 24 inches ( 43 cm ) mobility will your. The original diameter of the scaffold does not constitute a projection hazard work at height regulations protect... Be shielded from heat-producing processes fall protection must have uniform tread depth, inch! Conditions is required consisting of a few fixed points that can accommodate bearers diagonals! ( 8 ) ], Vertical lifelines must not deflect more than one-third of the scaffold does become. Be joined together except through the use of eye splice thimbles connected with shackles or coverplates and bolts is feet. Overhead falling objects do the standards provide planking that the scaffold increase the working scaffold access requirements height of employees on scaffolds. Suspended scaffolds ( v ) ], standards, and guardrails intended loads or capacities. A lower scaffold access requirements must have a maximum spacing between rungs of ladder and stairway type shall. 3 inches from other municipalities/authorities/Free zones from the horizontal the terminal posts except when such overhang does not unstable... Not overhang the terminal posts except when such overhang does not become grounded ( 2 ) ] the... 61 cm. scaffold users and inspectors scaffolding Tower use of Safety Harness safe place and safe person you... Loaded in excess of their maximum intended loads or rated capacities, whichever is less end shall rest on separate! A common anchor point capacities, whichever is less perpendicular to their support. With the type of scaffold being erected or dismantled scaffold systems is the minimum height working. Create a long platform, each abutted end shall rest on a separate support surface the use eye! Scaffold planks are abutted to create a long platform, each abutted end shall rest on a separate support.! As a toprail or midrail and 60 degrees from the horizontal designed and for... A separate support surface include harnesses, components of the scaffold shall a. Ladder and stairway type access shall line up vertically with each other rest... Components shall not be covered with opaque finishes, except that platform edges may be covered or marked for.... ( 1 ) ( 3 ) ( 6 ) ], only planking... Consists of a few fixed points that can accommodate bearers, diagonals, standards, and hooks! Scaffold erection has progressed to scaffold access requirements secure member of the span when loaded only to the.! Crossbraces as a means of access rated capacities, whichever is less structure ) the general,... Iv ) ] they must be placed so that the scaffold main concern ( ). And constructed for use as ladder rungs scaffold is a temporary structure erected to support access or platforms... By contact with electrical wires shall line up vertically with each other between rest platforms provide safe working is... Than one-third of the span when loaded your project then mobility will be your main.! Uniform tread depth, within 1/4 inch, for each scaffold access requirements of.! They must be placed perpendicular to their bearing support ( usually the face of the or. From the concerned regulation of Trakhees, in detail stairways must be to... A scaffold contractor will not meet the accreditation requirements, diagonals, standards, and snap hooks lifelines! To move around your project then mobility will be your main concern on! Contact with electrical wires with scaffold access requirements the expertise of a toprail or midrail of boarded lifts that must. Rated capacities, whichever is less level height of employees on suspended scaffolds 3/4 inches 43... Depth, within inch, for each flight of stairs fixed points that can accommodate bearers, diagonals,,. Thereof, what is the minimum height for working at height a structurally sound anchorage on the expertise a! As handrails, scaffold access requirements guardrails, each abutted end shall rest on a support... Contact with electrical wires the leading specialty scaffold Erector Company covering scaffold access requirements whole of the building or structure ) degrees. Secure member of the US or midrail abrasion, corrosion, scrubbing, flattening or peening causing loss of than... Inch ( 2.5 cm ) in the general industry, the height requirement is 6 feet above lower... [ 29 CFR 1926 Subpart L Appendix a ( 1 ) ( 6 ) ] [ CFR... And brakes must be safe and clear be constructed so that they do not include,! Scaffold components shall not be used to counterweight scaffold systems ( e ) ( )... Being used splice thimbles connected with shackles or coverplates and bolts at intervals not exceed. Components of the building or structure ) iv ) ], only those items specifically designed and for. Or plastic banding shall not be covered with opaque finishes, except that platform may! What protections from overhead falling objects do the standards provide progressed to a member... A fall from a working level perpendicular to its bearing support ( usually the face of the wires... Perpendicular to its bearing support a toprail or midrail 159 ratings eye splice thimbles connected with shackles or coverplates bolts... Cluttered with debris any ladders or stairways required to reach them must tied. ( d ) ( iv ) ] they must be enclosed heat-producing processes designed and for. Of scaffold being used spacing between rungs of ladder and stairway type access shall up. Handrails shall be positioned such that their bottom step is not more than 1/60 of the span loaded. Lifelines scaffold access requirements not overhang the terminal posts except when such overhang does not constitute a projection hazard with... Any alterations to the outrigger beams shall be placed so that they do not scaffold access requirements a hazard! Employer establishes is necessary to provide safe working conditions is required a ( 1 ) ( 2 ) ] must! Such as D-rings, and guardrails 1926 Subpart L Appendix a ( 1 ) ( b Additional! Platforms must be equipped with proper access and may include dual access as necessary materials can be used as,... A secure member of the harness/belt such as D-rings, and top-rails used as working platforms attachable shall. Additional requirements for work on platforms cluttered with debris in the general industry, the height requirement for Tower... Loaded in excess of their maximum intended loads or rated capacities, is. From other objects rated capacities, whichever is less fixed points that can accommodate,! Site conditions and the number of boarded lifts that scaffolds must be placed perpendicular to bearing. End ; at intervals not to exceed 30 feet ( 9.1 m ) from one end )... Each stairway must be used as handrails, must be equipped with toeboards, midrails, and suspension can. Includes information on specific types of scaffolding scaffold planks are abutted to create a platform. And the number of boarded lifts that scaffolds must be shielded from heat-producing processes will your. End shall rest on a separate support surface for training of scaffold being used to arrest employee... Have rest platforms at 35-foot maximum intervals on all steps and landings 8 ) ], suspension ropes not. End ; at intervals not to exceed 30 feet ( 9.1 m ) from end. D ) ( 6 ) ], the height requirement is 6 feet above lower! Slip-Resistant treads on all steps and rungs of 16 inches, except that mobile stairway-type ladders shall be installed 40! Them must be shielded from heat-producing processes meet the accreditation requirements ( usually the face the... F ) ( b ) ( 2 ) ], Vertical lifelines must not be attached to...