light gauge steel truss span tableslight gauge steel truss span tables
Fax: 817.676.9138, Privacy It is our goal to make using Cold Formed Trusses, specifically AdvanT Steel Cold Formed Trusses as easy as possible! << 0000042958 00000 n All the components used for the building structure are designed to your, specifications and stamped by a Structural Engineer licensed in the State in which, the project is erected. 2022 Clarkwestern Dietrich Building Systems LLC, Precut to exacting sizes and readily available, Flange widths include 1-5/8", 2", 2-1/2" and 3". Integrated TrusSteel software provides full design, modeling and project management functionality. profiles. Cold Formed Steel Floor Trusses | Advant Steel LLC | Light Gauge Bar Joist Welcome to AdvanT Steel Bar Joist Replacement Guide Updated UL H524 Adds Fire Ratings for: Concrete Slab Poured Gypcrete Plywood Sheathing Dropped Ceiling UL H524 Updated Span Table - Bar Joist Replacement Guide 4-25-2022.pdf ABOUT ADVANT Why Another Truss Section? ClarkDietrich S300 (CSS) members have a 3" flange and a 5/8" return and are used in very heavy loading and long spanning conditions. Example: Span Tables. below. Using the table goes as such, find your metal studs, look at your on center spacing to see what the allowable limit is. As a result, it requires soundproofing, and thermal insulation. These panels are made to your specifications and can include. praised by the GC and the installer. Ceiling Span Tables STEEL FRAMING INDUSTRY ASSOCIATION. 0000001377 00000 n If your project, requires a non-combustible floor truss or if you are able to eliminate sprinklers. Our Design/Build System provides you with one source for, the design, engineering, fabrication, and installation of the Light Gauge Steel, gauge steel C stud load & non-load bearing walls for the commercial and, residential markets. If lateral bracing is required for head-of-wall deflection track and a punchout is not spaced 12" from the top of stud, use strapping and blocking in lieu of CRC or Spazzer Bar lateral bridging. -d$L|k$o endstream endobj 65 0 obj 124 endobj 50 0 obj << /Type /Page /Parent 44 0 R /Resources 51 0 R /Contents 56 0 R /Thumb 27 0 R /MediaBox [ 0 0 612 792 ] /CropBox [ 0 0 612 792 ] /Rotate 0 >> endobj 51 0 obj << /ProcSet [ /PDF /Text /ImageB ] /Font << /F3 58 0 R /F5 52 0 R /F7 54 0 R /F9 57 0 R /F11 55 0 R >> /XObject << /Im3 61 0 R /Im4 62 0 R /Im5 63 0 R >> /ExtGState << /GS2 59 0 R >> >> endobj 52 0 obj << /Type /Font /Subtype /Type1 /Name /F5 /Encoding 53 0 R /BaseFont /Times-Bold >> endobj 53 0 obj << /Type /Encoding /Differences [ 1 /dotlessi /caron 39 /quotesingle 96 /grave 127 /bullet /bullet /bullet /quotesinglbase /florin /quotedblbase /ellipsis /dagger /daggerdbl /circumflex /perthousand /Scaron /guilsinglleft /OE /bullet /bullet /bullet /bullet /quoteleft /quoteright /quotedblleft /quotedblright /bullet /endash /emdash /tilde /trademark /scaron /guilsinglright /oe /bullet /bullet /Ydieresis /space 164 /currency 166 /brokenbar 168 /dieresis /copyright /ordfeminine 172 /logicalnot /hyphen /registered /macron /degree /plusminus /twosuperior /threesuperior /acute /mu 183 /periodcentered /cedilla /onesuperior /ordmasculine 188 /onequarter /onehalf /threequarters 192 /Agrave /Aacute /Acircumflex /Atilde /Adieresis /Aring /AE /Ccedilla /Egrave /Eacute /Ecircumflex /Edieresis /Igrave /Iacute /Icircumflex /Idieresis /Eth /Ntilde /Ograve /Oacute /Ocircumflex /Otilde /Odieresis /multiply /Oslash /Ugrave /Uacute /Ucircumflex /Udieresis /Yacute /Thorn /germandbls /agrave /aacute /acircumflex /atilde /adieresis /aring /ae /ccedilla /egrave /eacute /ecircumflex /edieresis /igrave /iacute /icircumflex /idieresis /eth /ntilde /ograve /oacute /ocircumflex /otilde /odieresis /divide /oslash /ugrave /uacute /ucircumflex /udieresis /yacute /thorn /ydieresis ] >> endobj 54 0 obj << /Type /Font /Subtype /Type1 /Name /F7 /Encoding 53 0 R /BaseFont /Times-Italic >> endobj 55 0 obj << /Type /Font /Subtype /Type1 /Name /F11 /Encoding 53 0 R /BaseFont /Times-BoldItalic >> endobj 56 0 obj << /Length 2622 /Filter /FlateDecode >> stream 05425 Cold-Formed Steel Trusses Floor Truss Spans Every TrusSteel floor truss is a custom design based upon the . AdvanT Steel LLC believes that we offer not only the best value/price for Cold Formed Steel Trusses versus C-stud and other Proprietary Shapesbut the best value/price for any Non-Combustible Floor or Flat Roof System versus any other product, whether it be structural steel bar joist, concrete, another CFS Trussor even CFS Joists. The elements of light gauge steel frame members need to be galvanized with zinc, aluminum or a combination thereof in order to provide long-term protection against corrosion. The AdvanT Truss section has many advantages over existing proprietary Cold Formed Steel Truss Shapes. O.C. runs perpendicular to the truss framing. Specification. 11) The truss web pattern used in the design is to be determined by the designer using . Web crippling capacity is based on a minimum bearing length of 3.5". Table 1 Minimum Thickness of Base Sheet Metal for Light Gauge Steel Frame Elements. Superior Truss & Panel can be, the answer to your roof framing needs including our industry leading one hour, one. S162 members are preferred for most curtain wall applications. Typically ProSTUD Drywall Framing is used for interior walls but the use of structural framing may be needed to meet taller requirements. We can also ship the material, loose to the jobsite. of Use. 0000001585 00000 n and 18 gauge (43 mils) base metal thick-ness is designated as 2-800L150-43: . 0000045291 00000 n Cost effective alternative to proprietary products. LIGHT GAUGE STEEL FLOOR TRUSSES Many state and local building codes are rapidly changing to non-combustible structures for commercial and multiple family residential facilities. Truss and bracing layouts with connection and installation details. The deep webbed PL-2 www.whirlwindsteel.com SUBJECT TO CHANGE WITHOUT NOTICE WHIRLWIND BUILDING COMPONENTS 8234 Hansen Rd. ceiling joists, or roof trusses. Recommended bridging is 8'0" on center maximum and needs to be in place before loading the floor system. % trailer << /Size 66 /Info 45 0 R /Encrypt 49 0 R /Root 48 0 R /Prev 98396 /ID[<31f0d5383b5fc70421c8502f686421b4>] >> startxref 0 %%EOF 48 0 obj << /Type /Catalog /Pages 44 0 R /Metadata 46 0 R >> endobj 49 0 obj << /Filter /Standard /R 3 /O (.m-@l=\(O/5) /U (5rrrj ` ) /P -1324 /V 2 /Length 128 >> endobj 64 0 obj << /S 68 /T 117 /Filter /FlateDecode /Length 65 0 R >> stream Superior Truss & Panel designs, engineers, prefabricates, delivers and installs lightgauge steel C stud load & non-load bearing walls for the commercial andresidential markets. PUBLICATION RG-9518 DECEMBER 1995 . The unique u-shaped, symmetrical chord section allows TrusSteel to deliver unequaled clear span capabilities and structural performance. Superior strength . Sheathing and Finish materials require a minimum stiffness to prevent cracking. We do not recommend using L/120 for walls taller than 10 feet. 33mil (20ga) and 43mil (18ga) framing products are produced with 33ksi steel. Spans are based upon continuous support of compression flange over the full length of the joist. Quick Twist Web Stiffeners may be required at supports and other point loads. Use iProSTUD in ClarkDietrich iTools to quickly lookup the interior framing system you need. for odd shaped spaces. Convert to service level load (ASD) = 16psf x 0.6 = 10psf Boston Group Hexaport International Ltd. ReRoof America, Inc. Truswal Systems Corp., The project architect or project specifications should note what the allowable deflection is for a given wall facing material. It is non-combustible material, but it must be protected from fire with fire rated sheeting since it loses its strength in fire. The studs for these framing systems must be able to withstand: Exterior curtain walls are non-axial load bearing and must be designed to withstand the highest lateral loads, wind or seismic, prescribed by the building code for the particular construction location and type. Corrugated metal decking and/or plywood attacheddirectly to light gauge steel trusses. We are so confident in this that we offer an online pricing tool to provide Design Guidance relative the span/depth/load of a project and an estimate of what one of our fabricators will charge for the finished AdvanT trusses! Loads of 7.5psf and 10psf are typically used for shaftwalls or interior lobby walls located in floors with multiple exterior doors. Structural Studs, may be used in a variety of applications and designs. Nonstructural (Non-load bearing) interior walls must be designed to withstand a minimum of 5 psf lateral load (perpendicular to the wall) for interior pressure as required by the International Building Code. Members smaller than 3-1/2" are unpunched unless otherwise specified at time of order. This is entirely due to CFS Trusses not offering the value they should. Need higher performance than conventional C shaped studs? We can build panels up to 50 tall and 12, wide with special hooks on top of the panels to, facilitate picking them up with a crane. 0000006140 00000 n Add in the ease of construction the Ultra-Span design brings and your project is positioned for success. Truss layouts consider ease of 0000000744 00000 n Span capacities to accommodate typical building layouts and floor/roof loads. Found in: Exterior Framing > Curtain Wall Framing Exterior Framing > Load-Bearing Framing Clips or ties for attaching trusses to the building structure. 0000006030 00000 n All door andwindow openings come already framed out with theexterior sheathing applied, we can also apply EIFS orthing brick to the panels. Custom designed to match roof and ceiling These are designed to permit wiring, piping, and bracing to pass through studs and joists without the need for drilling holes on the construction site. Superior Truss & Panel can bethe answer to your roof framing needs including our industry leading one hour, onelayer of drywall UL fire rated assemblies. Light Gauge Steel Trusses Designed and fabricated to exact specifications, light gauge trusses are an excellent choice for roof or floor systems in residential and commercial construction. Light framed structures allow the passage of sound which is undesirable. Wind and seismic resistance. _WBNucV-C 8yva*U/^,ZA4G^uhD{13z?$&_--lWA~\^M%t. /N 2 ClarkDietrich S137 (CWN) member have a 1-3/8" flange and 3/8" return and are used to support the exterior skin or cladding material (metal, stone, tile, glass, etc.) Specification Section 05 44 00. specification section 05 44 00 - cold Formed steel trusses. ClarkDietrich cold-formed C-studs, produced to AISI S240-15, for axial load-bearing and curtain-wall framing are pre-punched with punchouts at regular intervalsspecifically designed to allow for rapid installation of pipes, electrical conduit and wall bridging. Heavy-Duty Stud (HDS) alternative cost-effective framing system with superior strength. Superior Truss &, Panel can provide your complete roof structure, assembly as one single resource; ready to receive felt, paper and shingles. It is intended to provide span tables and construction details for L-shaped headers in residential and light commercial construction. 0000045486 00000 n Exceptional engineering support along with an extensive library of standard details, permits authorized TrusSteel fabricators to quickly design, bid and deliver quality roof components all backed by ITWs commitment to excellence. deliver and install (optional) light gauge steel trusses, mansards and canopies, structures for commercial and multiple family residential facilities. Floor Systems Light gauge trusses create a Extruded hole sizes range from 4-1/4" oval to 10" round based on member depth. 3) requires that the contractor enlist the services of a registered professional engineer to design the temporary bracing system. Non-combustible material. Based in Phoenix, Arizona, Westco Steel Systems provides quality Light Gage Steel Trusses throughout the Western States. Superior Truss & Panel, Inc. can build floor, panels in lengths of 60 and widths of 12 with metal, decking or plywood sheathing already attached to, the panel at our shop. These characteristics makes it versatile construction material. We design, engineer, pre-fabricate. Superior Truss &Panel can provide your complete roof structureassembly as one single resource; ready to receive feltpaper and shingles. with integrated mechanical, living, or storage space. In our first build, we used 600S162-43, i.e 6 18 gauge studs, 16 on center. 0000050644 00000 n Each Ultra-Span floor or roof truss is designed to take advantage of the greatest strength per pound of any CFS available. Utilizing high-strength steel with thicknesses ranging from 22 gauge (28 mil) to 12 gauge (97 mil), TrusSteel produces a lightweight yet strong floor truss system that reduces costs in design and installation. Log in to TheConstructor to ask questions, answer peoples questions, write articles & connect with other people. Many state and local building codes are rapidly changing to non-combustiblestructures for commercial and multiple family residential facilities. The weight of the cladding material (metal, stone, tile, etc.). ClarkDietrich S162 (CSJ) members have a 1-5/8" flange and a 1/2" return and are considered the industry standard. Additional member depths of 7-1/4", 9-1/4", 11-1/2", 13-1/2" and 14" are also available. << 8 A 3-1/2" bearing length was used at all support locations in the preparation of these tables. /Type /Catalog Bent metal for hips, ridges, valleys, sub-fascia, and shear collectors. /Linearized 1 Truss Spans 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' 2' 4' . 6750 Forum DriveSuite 305Orlando, FL 32821Ph. Check your projects Architectural Specifications and/or drawings for the minimum design load required. This Truss Load Table Guide illustrates how to read allowable load ratings for Aluminum and Steel Truss. We prepare all detailed wallpanel layouts and can include structural engineering stamps for size, gauge,layout, connections and details. Center of tail end punchout not less than 12" from end of stud. installation and allow for minor dimension descrepancies in the walls Installation clips built into the truss and all materials for truss to truss connections. Caution must be exercised when installing studs so knockouts align for bridging. Policy | Copyright 2015 Light Gauge The roof structure is generally a steel truss system which can be designed for metal sheets or tiles. /P 0 0000001691 00000 n Truss -open web load carrying assemblies that support roof or floor surfaces. Standard coating: CP60 (G60, CP90 & G90 available) Per AISI S240. (Compliant to ASTM C955 , but IBC replaced with AISI S200 in IBC 2015, AISI S240 in IBC 2018), Section A3 Material - Chemical & mechanical requirements (Referencing ASTM A1003/A1003M), Section A4 Corrosion Protection (Referencing ASTM A653/A653M), Section A5 Products - Thickness, shapes, tolerances, identification, Section C Installation - (Referencing ASTM C1007), Section F3 Delivery, Handling and Storage of Materials. The light gauge steel has great strength even thought its weight is low. These characteristics makes it versatile construction material. The structural steel frame can be erected quickly since the structural members are prefabricated and can be easily handled due to their lightweight. Structural track, usually in the same gauge as the joist, is used as rim or band enclosures. | Houston, TX 77075 | (Phone) 713.946.7140 | (US Wats) 800.324.9992 Purlin Load Tables Notes 1. They can be designed and fabricated to exact specifications and are an excellent choice for roof or floor systems in residential or commercial construction. It neither rot, shrink, warp nor suffer decomposition. The minimum available TradeReady Rim Track thickness is used. With the ever increasing cost of field labor and theassociated insurances, why not try and reduce thosecosts and use tilt up prefabricated curtain wallpanels. Back-to-back C-stud trusses offer the following advantages: High strength-to-weight ratio. ClarkDietrich S200 (CSW) members a 2" wide flange and a 5/8" return that provides a larger bearing surface for attaching sub-flooring or sheathing materials. in each table. The strength and flexibility of light gauge steel frame has led to increased spans, custom openings, curved wall, and different external faade treatments.